Skip to main content
Version: 2.10.0

Robus - Part 2: The topology management

Robus will rely on the unique ID distributed during the Luos engine's detection (Node_ID). Luos engine will need topological information to provide a unique ID during detection. Robus needs to be able to detect the nodes neighbors in the network and to share this information to Luos engine, allowing a proper topology detection.

Topology detection using PTP lines

Robus uses wires called PTP to poke the nodes neighbors and see if there is any.

The example below shows the process of assigning a node ID during the topology detection of three nodes. The starting node always has the node_ID set to the value 1.

luos_imgluos_img

In the Robus network, "poking" a node is done by a physical line called PTP, connected between one node to another. Those lines are only used during the topology detection process.

Here is a complete detection process. As you can see, during the node_ID assignation, the PTP lines are moving. Using this measure meant we can know which node is where in the network.

luos_imgluos_img

The example below shows the different line states during the steps needed to poke and get a response back from the poked node. The PTP line is shared by two nodes, so both of them will have an impact on the line level.

This drawing represents the different states of the different nodes, and the line level resulting in those different states.

luos_imgluos_img

Check the file port_manager.c for a better understanding of port management process and functions.